Lithium Battery Specs ePOWER B-TEC 200Ah
Lithium Battery Specs ePOWER B-TEC 200Ah
Specifications
Normal Specification | EPL-100BT-12V | EPL-125BT-12V | EPL-200BT-12V |
---|---|---|---|
Note: Specifications subject to change without notice. | |||
Nominal Voltage | 12.8V | ||
Nominal Capacity | 100Ah | 125Ah | 200Ah |
Cycle Life (DOD – 80% under controlled conditions) | ≥ 2000 Cycles | ||
Standard Charge Specification (Lithium profile charger required) | |||
Battery Charge Temperature | 0 ̴ 45°C | ||
Normal Charge Voltage CV/CC* | 14.40 ̴ 14.60V | ||
Standby (Float) Voltage | 13.50 ̴ 13.80V | ||
Maximum Charge Current | 50A @ 25°C for 30mins | 60A @ 25°C for 30mins | 150A @ 25°C for 30mins |
Recommended Charge Current for Maximum Life | ≤33A | ≤40A | ≤60A |
Standard Discharge Specification | |||
Battery Discharge Temperature | -20 ̴ 60°C | ||
Battery Output Voltage Range | 11.00 ̴ 14.60V | ||
Maximum Discharge Current | 100A @ 25°C ± 5°C for 30mins | 200A @ 25°C ±5°C for 30mins | |
Pulse Discharge Current | 450A for 1.0s | ||
Discharge Cut-off Voltage | ≤11.20V | ||
Circuit Protection | |||
The battery is supplied with a LiFePO4 Battery Management System BMS that can monitor and optimize each single prismatic cell during charge & discharge, to protect the battery pack from overcharge, over discharge & short circuit. Overall, the BMS helps to ensure safe and accurate operation of the battery. | |||
Over-Charge Protection | |||
Over-charge Protection Per Cell | 3.90V ± 0.03V | ||
Over-charge Release Per Cell | 3.60V ± 0.05V | ||
Over-charge Release Method | Discharge below release voltage | ||
Over-Discharge Protection | |||
Over-discharge Protection Per Cell | 2.80V ± 0.05V | ||
Over-discharge Release Per Cell | 3.20V ± 0.05V | ||
Over-discharge Release Method | Apply Charge/Voltage ≥12.8V | ||
Over Current Protection | |||
Discharge Over Current | 110A for 30s – 450A for 1s | 220A for 30s – 450A for 1s | |
Protection Reset Time | 5s Auto Release | ||
Over Current Release Method | Disconnect Load | ||
Over Temperature Protection | |||
Battery Discharge Over Temperature | Protection to 65°C ± 5°C | ||
Release at 50°C ± 5°C | |||
Battery Charge Over Temperature | Protection to 55°C ± 5°C | ||
Release at 45°C ± 5°C | |||
Short Circuit Protection | Auto release after 5s | ||
Mechanical Characteristics | |||
Dimensions | Length 318mm | 485mm | |
Width 165mm | 170mm | ||
Height 215mm | 245mm | ||
Weight | Approx 12.6 Kg | Approx 15.0 Kg | Approx 25.0 Kg |
Storage Information | |||
Temperature & Humidity Range | ≤ 30 days -20°C ̴ 35°C, 45 ̴ 75% RH | ||
≥ 30 days -10°C ̴ 30°C, 45 ̴ 75% RH | |||
Self-discharge Rate | ≤ 3% Per Month |